Cabinet handle projection is the distance hardware stands proud from a door or drawer front; finger clearance is the usable space behind or within the pull. For Capramont & Co hardware, check projection, centres, fixing type and door thickness before drilling, then send project details for custom centres, appliance pulls or unusual joinery.

Dimensional & Fit Engineering · Projection, Clearance & Fixings

Cabinet Handle Projection, Clearance & Fixings Guide

Resolve projection, usable grip space, fixing thread, front thickness and rear access before finished fronts are drilled. Projection and clearance are related but not interchangeable, and the fixing condition still needs to work with the actual cabinetry.

Riyadh and Jeddah

For Riyadh villas and branded residences and Jeddah homes or hospitality interiors, projection and fixing checks should be coordinated before larger joinery packages are drilled. Use this guide to review metric centres, door thickness, appliance-scale pulls, grip clearance, fixing depth and project-specific dimensions.

Centres · Projection · Finger Clearance · M5 Cabinet Pull / M6 Appliance Pull

01 · Technical Risks

Prevent drilling, clearance and fixing problems before order.

The same four checks repeat across drawers, doors, appliance panels and long pulls: projection, usable hand space, fixing route and actual front thickness.

01

Projection

How far the hardware stands proud from the cabinet face. Check adjacent fronts, corners, frames, circulation and appliance banks.

02

Finger clearance

The usable space behind, under or inside the pull. A product can project well but still feel tight if the grip path is shallow.

03

Fixing thread & rear access

Cabinet Pull sizes use M5; variants explicitly classified as Appliance Pull use M6. Rear access still needs to suit the installation.

04

Front thickness

Door, drawer-front or appliance-panel thickness affects final screw length, engagement and fitting suitability.

02 · Decision Framework

Projection and clearance are related, but they are not the same measurement.

Use product geometry and the real front condition together. Do not infer grip comfort from outward projection alone, and do not infer final screw length from M5 or M6 alone.

Projection

The distance from the cabinet face to the furthest outward point of the handle, knob, cup pull, C pull or T-bar.

Finger clearance

The usable hand space behind, under or within the hardware. Shape and underside geometry influence the usable path.

Fixing suitability

Depends on centres, thread, front thickness, final screw length and rear access. M5 applies to Cabinet Pull; M6 applies where the variant is explicitly an Appliance Pull.

03 · Hardware Type Comparison

Clearance and fixing checks by hardware type.

The visual form changes the engineering check. Use the selected PDP or technical sheet as the product-level release reference.

Hardware typeWhat to checkMain riskBest route
Cabinet handle / pullProjection, centre-to-centre, hand space, M5 fixing and repeated alignment.Looks correct on elevation but feels too shallow in use.Hardware Finder / PDP sheet
Appliance / tall-unit pullGrip strength, projection, panel weight, fixing position and M6 where explicitly classified Appliance Pull.Pull is undersized or fixing condition is unresolved for a heavy front.Send Project Details
C pull / finger pullFinger recess, rear access, front thickness, edge position and alignment.Low-profile appearance but tight access.Custom Centres Review
Cup pullInternal hand space, drawer height, fixing centres and drawer-bank alignment.Appears proportionate but feels cramped on larger drawers.Size & Placement
Knob / T-barSingle-point position, diameter or stem size, projection and repeat orientation.Correct fixing but poor hand position or inconsistent alignment.Physical sample

04 · Product Proof

Specification proof examples before drilling.

These product routes preserve the size, projection and technical-document evidence from the original page.

Beaufort Cabinet Handle

Beaufort Cabinet Handle

Centres: 92, 124, 156, 220, 284, 364 mm. Overall: 107, 139, 171, 235, 299, 379 mm.

Westbourne Cabinet Pull

Westbourne Cabinet Pull

Centres: 92, 124, 156, 220, 284, 364 mm. Overall: 114, 146, 178, 242, 306, 392 mm.

Beaufort C Pull

Beaufort C Pull

Centres: 32, 46, 58 mm. Overall: 44, 58, 70 mm.

Westbourne C Pull

Westbourne C Pull

Centres: 32, 46, 58 mm. Overall: 44, 58, 70 mm. Rear-fix; M5 where confirmed on PDP.

Farringdon Cup

Farringdon Cup

Centres: 50, 86, 138 mm. Overall: 60, 96, 148 mm.

Maddox Cabinet Handle

Maddox Cabinet Handle

Centres: 84, 124, 134, 204, 264, 322, 562 mm. Overall: 170, 210, 240, 310, 370, 450, 690 mm.

05 · Measured Engineering Comparison

Projection, section & fixing comparison.

Use this for first-pass dimensional screening. Exact size-level data on the selected PDP and technical sheet remains the release reference.

ProductFunctional roleStandard size routeProjection / sectionFixing
Beaufort Cabinet HandleCabinet Pull92–364 mm centres107–379 mm overall33–40 mm projection15 × 12 mm or 24 × 12 mm sectionM5 rear-fix
Westbourne Cabinet PullCabinet Pull92–364 mm centres114–392 mm overall24 mm projection24 mm profile heightM5 rear-fix
Beaufort C PullC Pull32 / 46 / 58 mm centres44 / 58 / 70 mm overall33 mm projection12 mm profile depthM5 rear-fix
Westbourne C PullC Pull32 / 46 / 58 mm centres44 / 58 / 70 mm overall36 mm projection15 mm profile depthM5 rear-fix
Farringdon CupCup Pull50 / 86 / 138 mm centres60 / 96 / 148 mm overall24 mm projection24 mm or 37 mm cup heightM5 rear-fix
Brunswick T-BarT-Bar56 / 65 mm overallSingle-point fixing33 / 40 mm projectionØ12.5 / Ø15.5 mm stemM5 rear-fix
Brunswick Cabinet KnobCabinet KnobØ25 / Ø31 / Ø38 mmSingle-point fixing32 mm projectionDiameter is the grip formM5 rear-fix
Harrington Cabinet HandleCabinet Pull / Appliance Pull106–616 mm centres170–690 mm overall40 or 50 mm projectionØ15.8 or Ø19 mm barM5 / M6M6 on Appliance Pull variants

Fixing rule: Cabinet Pull sizes use M5; variants explicitly classified as Appliance Pull use M6. Final screw length depends on actual cabinet-front or appliance-panel thickness and rear fixing access.

06 · Project Control

When to send drawings, elevations or door details.

Escalate the project where appliance panels, refrigerator panels, tall doors, fluted fronts, slim rails, inset cabinetry, existing holes, unusual front thickness or repeated elevations change the standard fitting condition.

Confirm the product data

  • Product name and collection
  • Size and overall length
  • Centre-to-centre
  • Projection
  • M5 Cabinet Pull / M6 Appliance Pull
  • Front thickness and rear access

Confirm the project condition

  • Existing holes or new drilling
  • Horizontal or vertical orientation
  • Slab, shaker, fluted or ribbed fronts
  • Appliance or tall-unit loads
  • Repeated drawer-bank alignment
  • Need for custom centres or schedule control

08 · FAQs

Projection, clearance and fixing questions.

Use the product page, technical sheet and reviewed project condition as the final release reference.

What is cabinet handle projection?
Projection is how far the handle, knob or pull stands out from the cabinet face. It affects grip comfort, adjacent-door clearance, traffic areas and appliance-panel use.
Is finger clearance the same as projection?
No. Projection is outward depth; clearance is usable hand space behind, under or inside the hardware. A pull can project sufficiently and still have a tight grip path.
Do all handles need the same projection?
No. Knobs, C pulls, cup pulls, standard handles and appliance pulls behave differently. Check the selected PDP or technical sheet before drilling.
What fixing thread is used?
Cabinet Pull sizes use M5. Variants explicitly classified as Appliance Pull use M6. Final screw length still depends on actual front thickness, rear access and required engagement.
When should the project be reviewed before ordering?
Use project review for appliance or refrigerator panels, tall doors, existing holes, custom or thick fronts, slim rails, fluted fronts, inset cabinetry and multi-room schedules.

Dimensional & Fit Engineering

Resolve projection, clearance and fixings before the cabinet front is drilled.

Confirm the selected product, fixing spacing, outward projection, usable grip path, M5/M6 route, front thickness and project condition. Escalate anything unusual before made-to-order production or drill release.